Motor
|
Synchronous (concentrated winding); Permanent magnet rotor
|
Synchronous (concentrated winding); Permanent magnet rotor
|
Motor efficiency
|
IE4 efficiency according to IEC/TS 60034-30-2 Ed. 1
|
IE4 efficiency according to IEC/TS 60034-30-2 Ed. 1
|
Frequency
|
50, 60 Hz
|
50, 60 Hz
|
Voltage / Rated Power
|
200-240 V / 3.0, 5.5, 7.5 HP (2.2, 4.0, 5.5 kW); 380-480 V / 3.0, 5.5, 7.5, 10.0 HP (2.2, 4.0, 5.5, 7.3 kW)
|
400-480 V / 11, 14, 18, HP (8.2, 10.6, 13.4 kW)
|
Rated ambient liquid temperature
|
104° F (40° C)
|
104° F (40° C)
|
Hydraulic
|
Guide pin; Adaptive N
|
Guide pin; Adaptive N
|
Discharge sizes
|
3", 4", 6" (80, 100, 150 mm)
|
3", 4", 6", 8" (80, 100, 150, 200 mm)
|
Speed range
|
200-240 V: 500-3000 rpm; 380-480 V: 500-3600 rpm
|
800-3000 rpm
|
Impeller material options
|
Hard-Iron; Duplex stainless steel
|
Hard-Iron; Duplex stainless steel
|
Seal system
|
Plug-in seal with double mechanical seals; Active Seal system
|
Plug-in seal with double mechanical seals; Active Seal system
|
Seal material options
|
WCCR/WCCR; RSiC/WCCR
|
WCCR/WCCR; RSiC/WCCR
|
Cooling system
|
Liquid-free heat-conduction technology
|
Closed loop cooling
|
Installation
|
Portable wet well installation (P); Portable free standing installation (S); Vertically mounted, permanent dry well installation (T); or Horizontally mounted, permanent dry well installation (Z)
|
Portable wet well installation (P); Portable free-standing installation (S); Vertically mounted, permanent dry well installation (T); or Horizontally mounted, permanent dry well installation (Z)
|
Sensors
|
Leakage detection in stator housing; Two independent temperature sensors
|
Leakage detection in inspection chamber; Two independent temperature sensors
|
Cable
|
Screened Flygt SUBCAB®, with integrated control wires – 30, 50, 60, 100 ft (10, 16, 20, 31 m)
|
Screened Flygt SUBCAB®, with integrated control wires – 30, 50, 60, 100 ft (10, 16, 20, 31 m)
|
Approvals
|
CE, FM, ATEX, IECEx, CSA, UKCA, UKEX
|
CE, CSA, UKCA
|