General | LTU801 |
---|---|
Power Supply/Supply | 10-30VDC |
Output Signal | 4-20mA |
Operating Temperature | -10° to 70° C/ 14 to 158° F |
Standard Measurement Ranges | 0-2m/0-6ft 0-5m/0-16ft 0-10m/0-33ft |
Max Measurement Range | 300m/984ft |
Standard Cable Lengths | 12, 25, 30, 50m/ 39, 82, 98, 164ft |
Diaphragm/Technology | Ceramics |
Accuracy | 0,1% |
Specific Approvals (except CE) | cUL, ATEX |
Other | LTU801 |
---|---|
Weight | High |
Scaleable/Possible to change the measurement range | Yes. Free scalable within 0-300m (Span min-max: 0,3-300m, meaning measurement ranges: min 0-0,3m to max 0-300m |
Diaphragm Protection | Large through holes |
VFD Suitable | Yes |
Lightning Protection | Built in lightning protection |
Degree of customization possibilities (range, cable etc.) | High |
Sea Water Ready | Yes |