UV Transmittance, Flowrate and Certifications | Specifications |
---|---|
UV transmittance range in % (1cm) | <20 to >75% |
Minimum flow rate (in m³/h) | 500 (3 mgd) |
Validation | UVDGM, NWRI |
UV Lamps and Monitoring Systems | Specifications |
---|---|
Lamp technology | Ecoray® LPHO |
Power per lamp (W) | 800 |
Lamp life (hours) | 14,000 |
UV intensity monitoring | One UV sensor per bank |
Control system | OptiDose |
UV System | Specifications |
---|---|
UV module protection class | IP 67 |
Module lifting | Integral, automatic or manual |
Lamp configuration | Staggered and inclined |
Level control device | Fixed or motorized weir |
Electrical Cabinets | Specifications |
---|---|
Electrical standards | CE, UL/cUL |
Ballast type | electronic, high efficiency, variable output (50 to 100% power) |
Common outputs | System status, lamp status, alarm messages, process values |
SCADA communication | Yes |
Supply voltage CE | 400/230 V, 50/60 Hz, 3 Ph, N, PE, TNS |
Supply voltage UL/cUL | 480Y/277 V, 60 Hz, 3Ph, 4-wire (L1, L2, L3, N, GND) |
Ambient air temperature | 5–50 °C / 41–122 °F |
Protection class | IP54, UL/cUL Type 12 (4X optional) |