General Information | PDOevoPLUS 900 to 9000 |
---|---|
Ozone production capacity | Up to 300 kg/h |
Cooling water inlet temp | 5-35°C; 41- 95°F |
Ozone concentration range | 2 - 6wt% (AIR); 6-15wt% (Oxygen) |
Feedgas | Air, LOX, PSA |
Dew point (feed gas) | < -70 °C; < -94 °F |
Feedgas (total hydrocarbons, THC) | < 60 ppmV |
System Components | PDOevoPLUS 900 to 9000 |
---|---|
System control | Siemens; Allen Bradley |
Technical Features | PDOevoPLUS 900 to 9000 |
---|---|
System regulation range | 1 - 100 % |
Humidity | < 90 % |
Ambient air temperature (min, max) | 5-35°C41-95°F |
Ozone installation location | Indoors |
Conformity | CE, UL |
Noise level (equivalent sound level - leq) | <85 |
Standards and Remote Control and Alarms | PDOevoPLUS 900 to 9000 |
---|---|
PLC | Siemens |
HMI | SIMATIC HMI Comfort Panels |
Bus system | Profibus, Modbus, Ethernet |
Common outputs and alarms | System Status, Lamp Status, Alarm Messages, Process Values |
Electrical Standards | PDOevoPLUS 900 to 9000 |
---|---|
Ozone electrical requirements | 3x400 / N / PE ±10% 50/60 Hz (TN-C or TN-S-net) |
Ozone electrical standards | EN, IEC, ISO, SN |
Protection class (cabinet / cell) | IP54 |
Power factor | 0.95 |
Materials Of Construction | PDOevoPLUS 900 to 9000 |
---|---|
Enclosure | powder coated steel |
Painting | RAL 7035 |
In contact with ozone | SS316 SS304 |
In contact with water | SS316 |
Options | PDOevoPLUS 900 to 9000 |
---|---|
PLC options | Siemens, Allen Bradley, Schneider |
Scada communication | Available |
Measurement | Ozone in water, Redox |
Reaction tank | Available |
Air preparation | Available |
Cooling systems | Open loop cooling, Closed loop cooling, Chiller |
Ozone destructor | catalytic, thermal |
Oxygen generator | Available |
Ozone contacting | Diffusors, Pump-Injection (venturi) |
Gas distribution system | automatic, manual |
Demistor | Available |