Flow Meters Flygt Flygt MagFlux Flow Meter

Specifications
Specifications

Specifications

General Flow Sensor Display Converter Connection Box
Sizes DN 15/1/2’’ to DN 1200/48’’ – EN or ANSI - - -
Flange Types Flange EN-1092-1/ ANSI B 16.5 CIass 150 / AWWA Class D - - -
Operating Temperature -10 to 80 °C / 15 to 176 °F - 20 to 60 °C /-5 to 150°F - 20 to 60 °C /-5 to 150°F - 20 to 60 °C /-5 to 150°F
Lining Hard Rubber - - -
Electrodes 1,4571 / AISI 316 TI - - -
Accuracy - - 0.25% -
Power supply - From MagFlux Converter 24 V AC, 50 / 60 Hz ± 10 % or 230/115 V AC, 50 / 60 Hz ± 10 % or 10-30 VDC -
Outputs - 1 pcs. RS-485 Modbus® RTU-mode 1 pcs. USB 1,1 type mini B, female 1 pcs. for Communication module 1 pcs. Active 4 - 20 mA 1 pcs. Voltage-free electromechanical relay (max. 50 V DC / 1 A) 1 pcs. Optically isolated MOSFET relay (max. 50 VAC / V DC / 120 mA) -
Enclosure Rating IP67, NEMA 6 / IP 68, NEMA 6P, IP 67, NEMA 6 (when mounted on Converter) IP 67, NEMA 6 IP 68, NEMA 6P (using gel potting kit part no. 838776). The flow meter can withstand unlimited immersion of up to 10 m (30ft) of water.
Standard Cable Lengths - - Communication cable 25m (82ft), 50m (164 ft), 200m (656 ft) MAX: 1000m (3300ft) Sensor cable 10m (30 ft), 25m (82 ft), 50m (164 ft) MAX: 50m (164ft) -
Display Type - 5 line LCD-display (64 x 128 pixels) - -
Datalogger - 32 Mb Flash memory, 168.000 loggings incl. date, time and value (curve display) - -
Automatic Electrode Cleaning Yes - - -
Specific Approvals (except CE) - - cUL -
General Information Flow Sensor Display Converter Connection Box
Flow rate Q min = 0,2 m/s (0.6 ft/s) Q max = 10 m/s (30 ft/s) - - -
Functionality Flow Sensor Display Converter Connection Box
Communication - MODBUS RTU MODBUS RTU -