Sizes
|
DN 15/1/2’’ to DN 1200/48’’ – EN or ANSI
|
-
|
-
|
-
|
Flange Types
|
Flange EN-1092-1/ ANSI B 16.5 CIass 150 / AWWA Class D
|
-
|
-
|
-
|
Operating Temperature
|
-10 to 80 °C / 15 to 176 °F
|
- 20 to 60 °C /-5 to 150°F
|
- 20 to 60 °C /-5 to 150°F
|
- 20 to 60 °C /-5 to 150°F
|
Lining
|
Hard Rubber
|
-
|
-
|
-
|
Electrodes
|
1,4571 / AISI 316 TI
|
-
|
-
|
-
|
Accuracy
|
-
|
-
|
0.25%
|
-
|
Power supply
|
-
|
From MagFlux Converter
|
24 V AC, 50 / 60 Hz ± 10 % or
230/115 V AC, 50 / 60 Hz ± 10 % or
10-30 VDC
|
-
|
Outputs
|
-
|
1 pcs. RS-485 Modbus® RTU-mode
1 pcs. USB 1,1 type mini B, female
1 pcs. for Communication module
|
1 pcs. Active 4 - 20 mA
1 pcs. Voltage-free electromechanical relay (max. 50 V DC / 1 A)
1 pcs. Optically isolated MOSFET relay (max. 50 VAC / V DC / 120 mA)
|
-
|
Enclosure Rating
|
IP67, NEMA 6 / IP 68, NEMA 6P,
|
IP 67, NEMA 6 (when mounted on Converter)
|
IP 67, NEMA 6
|
IP 68, NEMA 6P (using gel potting kit part no. 838776). The flow meter can withstand unlimited immersion of up to 10 m (30ft) of water.
|
Standard Cable Lengths
|
-
|
-
|
Communication cable 25m (82ft), 50m (164 ft), 200m (656 ft) MAX: 1000m (3300ft)
Sensor cable 10m (30 ft), 25m (82 ft), 50m (164 ft) MAX: 50m (164ft)
|
-
|
Display Type
|
-
|
5 line LCD-display (64 x 128 pixels)
|
-
|
-
|
Datalogger
|
-
|
32 Mb Flash memory, 168.000 loggings incl. date, time and value (curve display)
|
-
|
-
|
Automatic Electrode Cleaning
|
Yes
|
-
|
-
|
-
|
Specific Approvals (except CE)
|
-
|
-
|
cUL
|
-
|