It looks like you are coming from United States, but the current site you have selected to visit is Egypt. Do you want to change sites?

Yes, please. No. Keep me on the current site.

Cart

Subtotal (0 items):
$٠٫٠٠
TEST SITE
You will not be charged yet.

IQ Sensor Net System WTW IQ Sensor Net TetraCon® Conductivity Sensor

700 IQ/SW
Overview Specifications
Overview

Overview

WTW TetraCon Conductivity Digital IQ sensor for wastewater treatment plants, connectable to the IQ SENSOR NET. TetraCon® 700 IQ – digital 4 electrode conductivity measuring cell with flow-free operation, especially with high conductivity. 

Product Features
  • Rugged electrode-style conductivity probe for the IQ Sensor Net 
  • Flat surface reduces fouling
  • Large measurement range; 10 µS/cm.....500 mS/cm
  • Integrated NTC temperature sensor for temperature compensation
  • 2-year warranty on the probe
  • Highest linearity and very insensitive against contamination by 4-electrode system

This measuring technique has proven itself over the years and offers an interference-free operation, also and foremost at high conductivity values. The 4-electrode measuring cell is very insensitive to contamination. Based on the pressure resistance of up to 10 bars, there is nothing to stop you from mounting into pipes or on lines.

The sea water model includes the sensor for use in special media: All wetted parts are made of titanium and plastic and are therefore extremely resistant to corrosion.

Available Versions

SKU: 302500 - TetraCon® 700 IQ sensor for Conductivity
SKU: 302501 - TetraCon® 700 IQ SW - like 700 IQ, but sea water version

 

Specifications

Specifications

Specifications TetraCon® 700 IQ TetraCon® 700 IQ SW
Order No. 302500 302501
Measuring method 4-electrode cell 4-electrode cell
Measuring range 10 µS/cm - 500 mS/cm SAL: 0 … 70 TDS: 0 … 2000 mg/l 10 µS/cm - 500 mS/cm SAL: 0 … 70 TDS: 0 … 2000 mg/l
Cell Constants K = 0.917 cm-1, ±1.5% (in free solution) K = 0.933 cm-1, TetraCon® 700 IQ with EBST 700-DU/N flow-thru adapter K = 0.917 cm-1, ±1.5% (in free solution)
Resolution Depending on measuring range Depending on measuring range
Temp. measurement -5 ... +60 °C (23 ... 140 °F); NTC -5 ... +60 °C (23 ... 140 °F); NTC
Temp. compensation linear: 32 ... 140 °F (0 ... +60 °C) nonlinear: +5 °C ... 35 °C (acc. to DIN 38404) nonlinear: +35 °C --- +60 °C (acc. to WTW procedure) linear: 32 ... 140 °F (0 ... +60 °C) nonlinear: +5 °C ... 35 °C (acc. to DIN 38404) nonlinear: +35 °C --- +60 °C (acc. to WTW procedure)
Pressure Resistance 10 bar 10 bar
Ambient Conditions -5 ... +60 °C (23 ... 140 °F) -5 ... +60 °C (23 ... 140 °F)
Electrical connections 2-wire shield cable with quick fastener to sensor 2-wire shield cable with quick fastener to sensor
Electromagnetic Compatibility EN 61326, Class B, FCC Class A; Intended for indispensable operation EN 61326, Class B, FCC Class A; Intended for indispensable operation
Certifications CE, cETL, ETL CE, cETL, ETL
Mechanical Sensor head: PVC Sensor body: V4A stainless steel 1.4571 Protection rating IP 68 Sensor head: PVC Sensor body: V4A stainless steel 1.4571 Protection rating IP 68
Weight (without cable) Approx. 1.46 lb (660 g) Approx. 2.58 lb (1,170 g)
Warranty 2 years for defects in quality 2 years for defects in quality