YSI THM 1000 Selective VOC Analyzer

Overview Specifications
Overview

Ensures Safe Drinking Water without Sample Prep or Off-Site Analysis

YSI’s new THM 1000 Analyzer is an easy to operate, integrated Purge & Trap Gas Chromatograph (GC) that measures the four critical trihalomethanes (THMs) at ppb levels in less than a half-hour, on-site, right at your own facility. This integrated system is a powerful new tool that can help operators optimize water treatment at the plant and evaluate water age in the distribution system for improved monitoring of the formation of THMs, an EPA-regulated disinfection by-product.

Product Features
  • 30-minute analysis
    • Eliminates expensive and time-consuming off-site analysis for process control
  • Integrated Purge & Trap
    • No sample preparation required
  • Rapid operator feedback
    • Allows for immediate process adjustment capability
  • Customized PC software
    • Minimal operator interaction required to collect THM data
  • Push-button simplicity
    • Fast and easy operation; all-in-one sample purging, component separation, and data analysis
  • Dedicated instrument
    • Helps ensure the safety of public drinking water

The YSI THM 1000 offers sample purging, VOC (Volatile Organic Compound) component separation, and data analysis with the push of a button. Say goodbye to off-site analysis with accurate results delivered in only 30 minutes. This includes the analyzer, gas connection kit, calibration kit, and THM standard.

This integrated system is a powerful new tool that can help operators optimize water treatment at the plant and evaluate water age in the distribution system for improved monitoring of the formation of THMs, an EPA-regulated disinfection by-product.

THM 1000 Selective VOC Analyzer Highlights:

Push-button Simplicity:

Walk up analysis at the push of a button. Get precise THM results in 30 minutes. Streamlined analysis helps streamline the work you do to protect your community.

Integrated Purge & Trap:

No sample preparation required - reach ultra-low ppb detection levels without any prior prep work.

Rapid Feedback:

Quick, accurate, and inexpensive measurement of THMs creates numerous opportunities to improve the water treatment process. Fast results allow end users to quickly optimize water treatment chemical usage, saving money and eliminating worry.

Customized Software:

With an on-board touchscreen and external PC software to match, you can tailor your data gathering experience to match your needs.

 

Specifications

Specifications

THM 1000 Analyzer Specs
Size 15.8" l x 15.3" h x 9.4" w (401 mm x 389 mm x 239 mm)
Weight 16.5 lbs. (7.5 kg)
Power Universal AC input, 24 VDC internal
Power Consumption (Analyzer without Laptop) 150 W (peak), 120 VAC input, 24 VDC internal
Certifications ETL 61010 ? FCC part 15 Class A, ETLC, CE
Performance Specs
Measured Compounds Chloroform, Dichlorobromomethane, Dibromochloromethane, Bromoform
Accuracy Total THM: +/-15%*
Precision Total THM: 10% RSD
Calibration External calibration
Factory Calibration Range*** 5 ppb to 80 ppb for each THM compound
Sampling Analysis Time Approximately 30 minutes
Detector Type Surface Acoustic Wave (SAW) sensor
Requirements
Carrier Gas Helium, UHP grade
Supply Pressure 55 - 60 psig (3.8 - 4.1 bar)
Gas Volume per Sample Approximately 0.04 ft3
Water Sample Volume 40 mL
Environmental Operating the Analyzer within the recommended ranges ensures optimum instrument performance.
Recommended Operating Temperature Range 68°F to 85°F (20°C to 30°C)
Storage Temperature Range 5°C to 40°C (41°F to 104°F)
Relative Humidity <90% (non-condensing)

* Standard factory calibration.

** Up to 4,000 cycles from a single 300 cubic foot high pressure cylinder (DOT 3AA2400) based on an 11 minute purge cycle.

*** Instrument may be calibrated at a higher concentration if samples are suspected to have higher THMs.