Probe Specifications | FLOWTRACKER2 HANDHELD-ADV |
---|---|
Velocity Range | ±0.001 to 4.0 m/s (0.003 to 13 ft/s) |
Velocity Resolution | 0.0001 m/s (0.0003 ft/s) |
Velocity Accuracy | +/1% of measured velocity, +/- 0.25cm/s |
Acoustic Frequency | 10.0 MHz |
Sampling Volume Location | 10 cm (3.93 in) from the center transducer |
Minimum Depth | 0.02 m (0.79 in) |
Depth Measurement Range | 0 to 10m (0 to 32.81ft) |
Depth Measurement Resolution | 0.001m (0.003ft) |
Depth Sensor Accuracy | +/- 0.1% of FS (temperature compensated over full operating range); +/- 0.05% Static (steady-state at 25°C); Additionally compensated for real-time water velocity, temperature, salinity, and altitude |
Temperature Sensor | Resolution: 0.01° C, Accuracy: 0.1° C |
Tilt Sensor | Resolution: 0.001°, Accuracy: 1.0° |
Communication Protocol | RS-232 |
Operating/Storage Temperature | -20° C to 50° C (-4° F to 122° F) |
Probe Head Dimensions | (L)13.3 cm (5.22 in); (W) 6.1 cm (2.39 in); (H) 2.3 cm (0.90 in) |
Standard Cable Length | 1.5 m (4.92 ft) |
Weight in Air | 0.90 kg (1.98 lbs) |
Weight in Water | 0.30 kg (0.66 lbs) |
Handheld Specifications | FLOWTRACKER2 HANDHELD-ADV |
---|---|
Input Battery Voltage | 8 - 12 VDC |
Power Supply | 8 X AA Batteries |
Battery Life | 11 hours continuous use, typical settings1 |
Power Consumption | 1 W (Average) |
GPS: H. Position Accuracy | Up to 2.5 m (8.2 ft) nominal2 |
GPS: Frequency | L1 (1.575 MHz); SBAS compensation (WAAS, EGNOS, MSAS, GAGAN) |
LCD Resolution | 320 X 240 TFT Transmissive |
Bluetooth | Class 2, Range = 10 m (33 ft) nominal |
USB | Micro USB, IP-67 |
Battery Power to Probe | 8 - 12 VDC |
Data Transfer | RS-232 |
Data Storage | 16 GB. Up to 10k discharge measurements; Up to 10 million velocity samples |
Operating Temperature | Alkaline Batteries: -20° to 45°C (-4°F to 113°F); NiMH: -20° to 50°C (-4°F to 122°F) |
Storage Temperature | -30° to 70° C (-22° F to 158° F)3 |
Waterproof Rating | IP-67 (1m submersible) |
Handheld Dimensions | (L)10.4 cm (4.1 in); (W) 6.4 cm (2.5 in); (H) 23.7cm (9.3 in) |
Weight in Air | 0.75 kg (1.65 lbs) |
Weight in Water | -0.25 kg (-0.55 lbs) |
1Defined as power on with screen on at 100% brightness, ADV sensor pinging 50% of the time, GPS off, and no sleep periods. Actual battery life will vary depending on FT2 settings, manner of use and brand of battery.
2Ideal conditions and settings. GPS data are intended for approximate georeferencing and site ID.
3Remove batteries from FlowTracker2 handheld if storage temperatures exceeds operating temperature of Alkaline and NiMH batteries as stipulated above.
FlowTracker2 Software - PC
Comprehensive tables and time series graphs allow you to visualize and QC data during analysis. Change SmartQC criteria and edit data—yet rest assured the original file will always remain untouched. FT2's open-source JSON file format is ready to be read into any organization's database, and is supported with direct import to Hydstra and WISKI.
Graph, view, analyze, and edit data collected with the FlowTracker2 instrument, and generate reports using the Windows-based FlowTracker2 software. Station data as well as point measurements can be edited, yet the original data file will always be preserved. View beam checks and perform many other diagnostic and QC checks whose criteria can also be manipulated in software settings. Generate or edit template files in the office which can be uploaded to the FlowTracker instrument and used to save time in the field. Export data to *.CSV format or import the FlowTracker's open-souce JSON files directly to databases.
November 2024 improvements include:
Recent updates also included:
Handheld Software
Desktop Software
FlowTracker2 software includes language support for English, Spanish, French, Portuguese, German, Italian, Russian, Chinese (traditional and simplified), Japanese, Korean, Polish, Catalan, Romanian and Greek. A built-in multi-language translator tool can be used to customize software for additional languages and regional terminology.