Overview Specifications Solutions
Overview

Overview

Product Features
  • ​Ozone production of 0.5 to 20 lbs./day 3 to 400 g/hr
  • Compact skid mounted design
  • Low installation and maintenance requirements
  • Low investment and operating costs
  • High concentration ozone generation
  • Engineered for permanent operation

WEDECO "plug and play" OCS unit

​Wedeco Ozone Complete Systems (OCS) are designed to meet the customer requirements, and are a ready-to-install and easy to operate ozone unit with a high reliability. OCS units are ”plug and play” solutions for customers looking for easy process integration of ozone applications into their processes.

The system can work automatically after starting with the main switch or an external signal.

OCS units are equipped with an ozone monitor detecting ozone in ambient air, complies with CE-EMVG and ZH 1/474, and is pre-tested before shipment. All components are mounted on a stainless steel frame and are ready for connection.

Standard components of Wedeco OCS units are an ozone generator (up to GSO 30), feedgas supply via oxygen generator, introduction system with pump and injector, ambient air monitoring, electric controls with signal exchange, stainless steel frame with internal piping and wiring, and pipework and wiring. Optional accessories include ozone concentration monitoring (gas/water), reaction and degassing tanks in different sizes, residual ozone destruction in off gas, and stainless steel cabinet and piping.

Specifications

Specifications

General Information OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
Cooling water inlet temp 5-35°C; 41- 95°F 5-35°C; 41- 95°F 5-35°C; 41- 95°F 5-35°C; 41- 95°F
Ozone production, nominal [g O3/h] (ppd) 0,2 - 50 0,2 - 30 5 - 100 5 - 400
Feedgas included included included included
Feedgas inlet pressure 2,5 - 3,5 barg (g); (xxxx PSI(g)) 2,5 - 3,5 barg (g); (xxxx PSI(g)) 2,5 - 3,5 barg (g); (xxxx PSI(g)) 2,5 - 3,5 barg (g); (xxxx PSI(g))
Dew point (feed gas) < -70 °C; < -94 °F < -70 °C; < -94 °F < -70 °C; < -94 °F < -70 °C; < -94 °F
Dimensions l x h x w (mm); l x h x w (ft) 1150 mm x 1710 mm x 700 mm 2150 mm x 1900 mm x 900 mm 950 mm x 1710 mm x 1040 mm 950 mm x 1710 mm x 950 mm
Cooling medium Air / Water Air / Water Water Water
System Components OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
System control Siemens Siemens Siemens Siemens
Technical Features OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
System regulation range 15 - 100 % 15 - 100 % 15 - 100 % 15 - 100 %
Humidity < 70 % < 70 % < 70 % < 70 %
Ambient air temperature (min, max) 5-35°C 41-95°F 5-35°C 41-95°F 5-35°C 41-95°F 5-35°C 41-95°F
Ozone installation location Indoors Indoors Indoors Indoors
Conformity CE CE CE CE
Standards and Remote Control and Alarms OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
PLC Siemens Siemens Siemens Siemens
Bus system Profibus, Modbus, Ethernet Profibus, Modbus, Ethernet Profibus, Modbus, Ethernet Profibus, Modbus, Ethernet
Common outputs and alarms System Status, Alarm Messages, Process Values System Status, Alarm Messages, Process Values System Status, Alarm Messages, Process Values System Status, Alarm Messages, Process Values
Electrical Standards OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
Ozone electrical requirements 230 / N / PE ±10% 50/60 Hz (TN-C or TN-S-net) 230 / N / PE ±10% 50/60 Hz (TN-C or TN-S-net) 230 / N / PE ±10% 50/60 Hz (TN-C or TN-S-net) 230 / N / PE ±10% 50/60 Hz (TN-C or TN-S-net)
Protection class (cabinet / cell) IP32 IP32 IP32 IP32
Power factor 0.95 0.95 0.95 0.95
Materials Of Construction OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
Enclosure powder coated steel powder coated steel powder coated steel powder coated steel
Painting RAL 7035 RAL 7035 RAL 7035 RAL 7035
In contact with ozone SS316 SS304 SS316 SS304 SS316 SS304 SS316 SS304
In contact with water SS 316 SS 316 SS 316 SS 316
Options OCS Systems Skid 1.1 OCS Systems Skid 1.2 OCS Systems Skid 2 OCS Systems Skid 3
PLC options Siemens, Allen Bradley, Schneider Siemens, Allen Bradley, Schneider Siemens, Allen Bradley, Schneider Siemens, Allen Bradley, Schneider
Scada communication Available Available Available Available
Measurement Ozone in water, Redox Ozone in water, Redox Ozone in water, Redox Ozone in water, Redox
Reaction tank Available Available Available Available
Air preparation Available Available Available Available
Cooling systems Open loop cooling, Closed loop cooling, Chiller Open loop cooling, Closed loop cooling, Chiller Open loop cooling, Closed loop cooling, Chiller Open loop cooling, Closed loop cooling, Chiller
Ozone destructor catalytic, thermal catalytic, thermal catalytic, thermal catalytic, thermal
Oxygen generator Available Available Available Available
Ozone contacting Diffusors, Pump-Injection (venturi) Diffusors, Pump-Injection (venturi) Diffusors, Pump-Injection (venturi) Diffusors, Pump-Injection (venturi)
Gas distribution system automatic, manual automatic, manual automatic, manual automatic, manual
Demistor Available Available Available Available
Solutions

Solutions

Recommended Solutions